ECE ILLINOIS Facebook ECE ILLINOIS on Twitter ECE ILLINOIS Alumni and Friends on LinkedIn ECE ILLINOIS Instagram

Contact Info

Brad Petersen
Director of
Communications
2052 ECE Building
306 N. Wright Street
Urbana, IL 61801
Phone: (217) 244-6376
bradp@illinois.edu

Contact Info

Meg Dickinson
Communications Specialist
2016 ECE Building
306 N. Wright Street
Urbana, IL 61801
Phone: (217) 300-6664
megd@illinois.edu

Subscribe to ECE ILLINOIS News

Recent News

New ECE class gives students an in-depth look at the engineering process

New ECE class gives students an in-depth look at the engineering process

Starting this semester, ECE ILLINOIS will offer students an opportunity to study the engineering design process and possibly get a head start on their Senior Design projects with a new class called ECE 398, Special Topics in ECE.

New imaging method sheds light on cell growth

 Subscribe to ECE ILLINOIS News

By Liz Ahlberg, U of I News Bureau
August 26, 2011

  • A team of researchers led by Assistant Professor Gabriel Popescu have developed SLIM, a new imaging method to measure cell mass.
  • SLIM is noninvasive and can provide insight on cells as they function naturally.
  • The researchers hope to apply their new knowledge of cell growth to different disease models.

Gabriel  Popescu
Gabriel Popescu

University of Illinois researchers are giving a light answer to the heavy question of cell growth.

Led by ECE Assistant Professor Gabriel Popescu, the research team developed a new imaging method called spatial light interference microscopy (SLIM) that can measure cell mass using two beams of light. Described in the Proceedings of the National Academy of Science, the SLIM technique offers new insight into the much-debated problem of whether cells grow at a constant rate or exponentially.

SLIM is extremely sensitive, quantitatively measuring mass with femtogram accuracy. By comparison, a micron-sized droplet of water weighs 1,000 femtograms. It can measure the growth of a single cell, and even mass transport within the cell. Yet, the technique is broadly applicable.

“A significant advantage over existing methods is that we can measure all types of cells – bacteria, mammalian cells, adherent cells, nonadherent cells, single cells and populations,” said Mustafa Mir, a graduate student and a first author of the paper. “And all this while maintaining the sensitivity and the quantitative information that we get.”

Unlike most other cell-imaging techniques, SLIM – a combination of phase-contrast microscopy and holography – does not need staining or any other special preparation. Because it is completely non-invasive, the researchers can study cells as they go about their natural functions. It uses white light and can be combined with more traditional microscopy techniques, such as fluorescence, to monitor cells as they grow.

“We were able to combine more traditional methods with our method because this is just an add-on module to a commercial microscope,” Mir said. “Biologists can use all their old tricks and just add our module on top.”

Illinois researchers developed a novel imaging technique that can quantitatively measure cell mass with light. Photo courtesy of the Quantitative Light Imaging Laboratory.
Illinois researchers developed a novel imaging technique that can quantitatively measure cell mass with light. Photo courtesy of the Quantitative Light Imaging Laboratory.

Because of SLIM’s sensitivity, the researchers could monitor cells’ growth through different phases of the cell cycle. They found that mammalian cells show clear exponential growth only during the G2 phase of the cell cycle, after the DNA replicates and before the cell divides. This information has great implications not only for basic biology, but also for diagnostics, drug development and tissue engineering.

The researchers hope to apply their new knowledge of cell growth to different disease models. For example, they plan to use SLIM to see how growth varies between normal cells and cancer cells, and the effects of treatments on the growth rate.

Popescu, a researcher in the Beckman Institute for Advanced Science and Technology, is establishing SLIM as a shared resource on the Illinois campus, hoping to harness its flexibility for basic and clinical research in a number of areas.

“It could be used in many applications in both life sciences and materials science,” said Popescu, who also is a professor of physics and of bioengineering. “The interferometric information can translate to the topography of silicon wafers or semiconductors. It’s like an iPad – we have the hardware, and there are a number of different applications dedicated to specific problems of interest to different labs.”
Co-authors on the paper include graduate students Zhuo Wang, Zhen Shen, and Michael Bednarz, along with electrical and computer engineering professor Rashid Bashir, physics professor Ido Golding and cell and developmental biology professor Supriya G. Prasanth.

The National Science Foundation and the Grainger Foundation supported this work.

Editor's note: media inquiries should be directed to Brad Petersen, Director of Communications, at bradp@illinois.edu or (217) 244-6376.

 Subscribe to ECE ILLINOIS News